Product - Fibershield-S

Fibershield®-S

The space creating textile fire protection curtain that leads around the corner

Product description

Fire protection that leads around corners: The floor space of the closure can be realised in a rectangular and polygon-shape with angles between 30° and 150°. No support elements are required despite the corner design. In addition to a closed polygon shape, open systems can also be realised that close against the wall by installing special guide rails. The fire protection curtain can be closed without any external energy by means of the 'Gravigen' drive system that is included as standard. The Fibershield-S complex allows for complex sealing geometries to be realised, while also complying with the requirement of closing off a space for more than 90 minutes.

Fibershield-S

Type

Textile fire protection curtain

Achievable protection goals

EI - with fire load free zone • EW 90 • EI - with sprinklers

Fabric

Ecotex 1100 A2 • Heliotex

Fire load free zone

Protex/Ecotex: EI 30/60/90min 100/150/200 cm • Heliotex: EI 30/60/90min 20/30/50 cm

Verification

IBS 08062416 • UL 10 (b) (2009) • UL 10 (c) (2009) • UL 10 (d) (2009) • NFPA 252 (2012)

Closing direction

From top to bottom

Closing cycles

C1

  • Fibershield-S
  • Fibershield-S
  • Fibershield-S
  • Fibershield-S
  • Fibershield-S
Constructive system design - System drawing

1Smoke detector2Casing3Side guids4Tubular motor5Fabric6Closing element7Coil8Control module9Control with operating unit10Manual releaseSLSystem length


1Smoke detector2Casing3Side guids4Tubular motor5Fabric6Closing element7Coil8Control module9Control with operating unit10Manual releaseSLSystem length

Fabric

System width

Drop length (AL)

t

h

Ecotex 1100 A2

< 50 m

< 3 m

490 mm

125 mm

Ecotex 1100 A2

< 50 m

> 3 m - ≤6 m

490 mm

225 mm

Heliotex EW 90

< 50 m

< 2.2 m

490 mm

125 mm

Heliotex EW 90

< 50 m

> 2.2 m - ≤2.5 m

490 mm

225 mm

Heliotex EW 90

< 50 m

> 4.5 m - ≤6 m

490 mm

450 mm

Closing strips

Standard

Standard

Closing strips - Standard

Special

With light spots or light strip

 - With light spots or light strip

Casing

Standard

Casing (open)

Casing - Casing (open)

hfrom tabled290 mmt490 mm

Casing (closed)

Casing - Casing (closed)

hfrom tabled290 mmt490 mm

Special

Casing EI (open)

 - Casing EI (open)

h240 mmd560 mmt600 mm

Casing EI (closed)

 - Casing EI (closed)

h240 mmd560 mmt600 mm

Locking equipment (optional)

 - Locking equipment (optional)

h125 mmd290 mmt490 mmSInfrarot Sicherung

Guide rails

Standard

Guide for open polygons

Guide rails - Guide for open polygons

a117 mmb278 mm

References

Product - Segeberger Clinics